Study on the Relationship between Aspects, Orientation,Type, and Unit Position toward to Indoor Air Quality in Flat

Loading...
Thumbnail Image
Date
2013-05
Journal Title
Journal ISSN
Volume Title
Publisher
Scientific Research
Abstract
Thermal factor is one of the main factors of the green building concept. The purpose of this research is to test building performance through design aspect that influences thermal comfort, the design aspects include: orientation, building type, and position of the flat. Method used in this research is covariance analysis, testing the influence of factor variable toward respond variable (indoor temperature) with taking outdoor temperature as concomitant variable. The cases tested on this research are Cigugur Tengah, Industri Dalam, and Sarijadi flats. Result of covariance analysis shows that the building orientation factor variable is most influentially variable toward thermal comfort, compared with building type factor variable; even the unit position factor variable has no significant influence toward thermal comfort.
Description
Keywords
Orientation, Building Type, Unit Position, Thermal, Flat House, Selective Design
Citation
Technology and Investment, 2013, 4, 85-91