    The Role of Ultrasound and Air Leak Measurement in Assessing Lung Expansion after Thoracic Surgery

    Thumbnail
    View/Open
    Full Text (306.5Kb)
    Date
    2015-08
    Author
    Chavarín, Abraham
    Molins, Laureano
    Mier, Jose M.
    Fibla, Juan J.
    Izquierdo-Vidal, Cristina
    Simon, Cristina
    Guirao, Angela
    Hernandez, Jorge
    Metadata
    Show full item record
    Abstract
    Objective: To determine if lung ultrasound semiology is applicable to the post-surgical hemithorax, and its value in the evaluation of lung expansion in the postoperative period when paired with the use of digital chest drain systems. Methods: Prospective observational study including all patients undergoing thoracic surgery from June 2012 to March 2013. Patients undergoing pleurodesis or hemodynamically unstable were not considered candidates. Final inclusion in the study was based on the availability of digital chest drain system. A transthoracic lung ultrasound evaluation of the anterior and anterolateral windows was performed 20 minutes after chest drain placement. Presence or not of lung sliding and air leak values taken from the digital chest drain system were recorded. Data were submitted to a binomial classification test for analysis. Results: Forty-nine patients were included, yielding a total of 64 hemithoraces. Lung sliding was seen in 53 cases (82.8%), and an air leak value of 20 ml/min or less in 56 cases (87.5%). Sensitivity was 92.8% (95% CI: 82.6% to 97.9%) and specificity 87.5% (95% CI: 47.3% to 97.9%). Positive predictive value was 98.1%, and negative predictive value was 63.6%. Conclusions: Transthoracic lung ultrasound is a useful technique that can complement the use of digital chest drain systems in the evaluation of post-surgical lung expansion. The incorporation of lung ultrasound can greatly reduce the need for chest radiographs in thoracic surgery departments
    URI
    http://dx.doi.org/10.4236/ss.2015.68052
    http://hdl.handle.net/123456789/1647
    Collections
    • Public Health and Nursing [86]

    University of Embu copyright ©  2021
    Contact us | Send Feedback
    Library ER 
    Atmire NV
     

     

    Browse

    All of RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    University of Embu copyright ©  2021
    Contact us | Send Feedback
    Library ER 
    Atmire NV