Show simple item record

dc.contributor.authorAnthimidis, George
dc.contributor.authorVarsamis, Nikolaos
dc.contributor.authorGeorgakoudi, Eleni
dc.contributor.authorFahantidis, Epameinondas
dc.contributor.authorIoannidis, Kostas
dc.contributor.authorBasdanis, George
dc.date.accessioned2018-06-27T09:14:32Z
dc.date.available2018-06-27T09:14:32Z
dc.date.issued2015-11
dc.identifier.citationSurgical Science, 2015, 6, 483-488en_US
dc.identifier.issn2157-9415
dc.identifier.urihttp://dx.doi.org/10.4236/ss.2015.611070
dc.identifier.urihttp://hdl.handle.net/123456789/1645
dc.description.abstractBackground: Procedure for prolapse and hemorrhoids (PPH) has emerged as an alternative surgical treatment of symptomatic hemorrhoids. The operative technique along with the device to be used is constantly evolving. Aim: The aim of the present study was to evaluate results of PPH using a modified technique and an innovative circular stapler. Material and Methods: A prospective, comparative study of patients undergoing PPH for symptomatic Grade II and Grade III internal hemorrhoids with either 32 mm or 34 mm stapler diameter (Circular Stapler for HemorrhoidsCSH 32/34) during a 36 month period (1/1/2012-1/1/2015) was performed. A modified operative technique using two purse string sutures was employed. Patients were evaluated and compared in terms of postoperative complications, operation time, length of hospital stay and time to return to normal activities. Results: A total of 100 patients were included: 50 in the CSH 32 group and 50 in the CSH 34 group. Complication rates were equal for both stapler diameters (32 mm and 34 mm). Serious or life threatening complications were not encountered and need for reintervention was never met. Operation time, length of hospital stay and time to return to normal activities were similar in both groups. Conclusions: Our study suggests that there are no significant differences between the two available diameters of a new-fangled circular stapler, using a modified technique. It seems that progress of hemorrhoidal staplers has led to a step towards the goals of implement and from then on complications of surgical practice could be merely a matter of operative technique.en_US
dc.language.isoenen_US
dc.publisherScientific Researchen_US
dc.subjectHemorroidsen_US
dc.subjectStapleren_US
dc.subjectProcedure for Prolapse and Hemorrhoidsen_US
dc.titleState of the Art Hemorrhoidal Stapler Using a Modified Technique: A Step towards the Goals of Implementen_US
dc.typeArticleen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record